Infrastructure

The activity of the centre relies on 3 work platforms, as follows:

1. Smart microgrid system inteligentă for integration of renewable energy sources (RES) into distributed networks, with data measurement, control and processing platform, consisting in the following stands:

• Stand for systems for the conversion of eolian energy with synchronous generator with permanent magnets (GSMP). Include un GSMP de 4.5kW antrenat de un emulator de turbină eoliană, convertoare electronice de putere pentru conectarea generatorului la MR, un sistem de control în timp real (dSPACE DS1103 şi Matlab/Simulink), sistem de achiztţie şi alte echipamente specifice. (2011)

• Stand for the conversion of eolian energy with asynchronous generator double power supply (GADA) - Includes a GADA of 7.5kW powered by an eolian turbine emulator, electronic power convertors for connecting the generator to the MR, real time control system (dSPACE DS1103 and Matlab/Simulink), acquisition system and other specific equipment. (2011)

• Stand photovoltaic systems (PV) - Includes a PV emulator (programmable DC power supply 600V/6A), electronic power converter for interfacing the MR generator, real time control system (dSPACE DS1103 and Matlab/Simulink), acquisition system and other specific equipment. (2011)

• Stand for micro-hydro-power plants with asynchronous generator in short-circuit (GASC) - Includes and hydro-turbine emulator that powers 3.3kW GASC, an automation panel for connecting the generator to the MR and an electronic power converter, real time control system (dSPACE DS1103 and Matlab/Simulink), acquisition system and other specific equipment. (2011)

• Stand for power circulation control - Includes and active programmable 9kW charge, a battery based electrical storage system, a battery of phase capacitors, a synchronous static compensator, a real time control system (dSPACE DS1103 and Matlab/Simulink), acquisition system and other specific equipment (2011).

• Four-quadrant power convertor The electronic converter with a nominal power of 10kVA allows synthetising a three-phase voltage system and can operate in all the four quadrants of the P/Q characteristic. The Equipment includes a hardware part with a central voltage convertor of PWM modulation and a real time dSPACE DS1103 subsystem. (2016)

• Power Analyser - Yokogawa WT1800-6(2011)

• Phottovoltaic plant connected to the network, with a local electrical energy storage system - Includes 32 photovoltaic panels with an installed power of 8kWp, a 4.6KW PV inverter, a bidirectional Sunny Island de 6kW inverter, and a 48V/400Ah Li-Ion accumulator storage system. (2017)

Sistem microrețea inteligentă 1
Sistem microrețea inteligentă Copy

• Davis Instruments Vantage Pro2 Aktiv Wireless Weather Station - Includes sensors for solar radiation, wind direction and speed, humidity, etc. (2019)


2. Integrated system for testing conducted electromagnetic perturbations of electrical and electronic equipment consisting in the following stands:

• Stand for testing electrostatic discharge - Electrostatic discharge generator gun (ESD 30N/P30N (1-8 kV); ESD kit (gun adaptor, resistive cable, connexion cabels -2 pieces, dischargers -3 pieces) RCN1, EAS 30; vertical air discharge plate VCP, series V1139110864 (2012);

• Stand for testing high voltage - 6 kV/0.5 J, VSS 500N6, series V1139110872 simulator, 10 kV/ 165 J, tip VSS 500N10.3, series V1139110873 (2012);

• EMC reflective enclosures - Reflective chamber (6.1x4x3) m;
Reflective chamber (4x4x3) m;
Supply panel; (2012)

• Stand for harmonics and flicker testing
30 kVA three-phase multifunctional source, three-phase flicker impedance, 32 A trhree-phase and harmonics analyser (2012)

• Stand for low frequency immunity testing Continuous wave simulator; 6 dB Attenuator; R-100simulator calibration set; 32 A coupling/decoupling grid; Calibration adaptor for CDN-M5/32 A; RF, 100W injection probe; R-100 calibration set for the injection probe. (2012)

• Stand for testing voltage variations /burst,surge, power fail, magnetic fields / Voltage variations; coupling/decoupling grid for burst and surge; capacitive coupling grid; coupling grid for surge; 10 A current transformer; 100 A current transformer; magnetic field antenna; callibration kit; MotorVariac (2012);

Sistem integrat de testare 1
Sistem integrat de testare  2

3. Automatic criogenic system with closed helium circuit for measurement of electrical and magnetical properties of materials at high and low temperatures, respectively inert-Pure Lab HE2 Glove Box work station.

• Automatic criogenic system with closed helium circuit for measurement of electrical and magnetical properties of materials at high and low temperatures - He closed circuit criogenic system; Magnetic field up to 7 T, temperature in 2-700 K; VSM with sensitivity up to 10-7 uem, Susceptometer in alternating magnetic field; Measurement of conduction properties with temperature and magnetic field; thermal transfer properties in 2 – 350 K and measurement domains: 1 μW/K – 1W/K. (2011)

Sistem automat criogenic

• Inert-Pure Lab HE2 Glove Box work station - Gas Purifier < 1ppm O2 and H2O; Large Vacuum Chamber; Rotary Vane Vacuum Pump; Variable Speed 0-60 CFM Circulation System (2011).

Statie de lucru in atmosfera inerta